INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.continental replaces.com • ask@continental re.on.ca
1.24B
$10.00
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
!
WARNING
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
If the information in these instructions
are not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACES HEATERS.
BCDV42N
NATURAL GAS
BCDV42P
PROPANE
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - OPERATING INSTRUCTIONS

1W415-0778 / D / 09.13.12INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.NEVER LEAVE CHILDREN OR O

Page 2 - TABLE OF CONTENTS

10W415-0778 / D / 09.13.123.2 TYPICAL VENT INSTALLATIONS18" MAX38 1/4" MIN PLUS RISE*35 1/2"40FTMAX3FTMIN16" MINNOTE: When termin

Page 3 - 1.0 INSTALLATION OVERVIEW

11W415-0778 / D / 09.13.123.3 SPECIAL VENT INSTALLATIONS3.3.1 PERISCOPE TERMINATIONUse the periscope kit to locate the air termination above grade. T

Page 4 - 2.0 INTRODUCTION

12W415-0778 / D / 09.13.123.4 MINIMUM AIR TERMINAL LOCATION CLEARANCESINSTALLATIONSCANADA U.S.A.A 12” 12” Clearance above grade, veranda porch, deck

Page 5 - 2.2 GENERAL INSTRUCTIONS

13W415-0778 / D / 09.13.123.5 VENT APPLICATION FLOW CHART13.1TOP EXITHorizontal TerminationVertical TerminationVertical rise is equal to or greater t

Page 6 - 2.3 GENERAL INFORMATION

14W415-0778 / D / 09.13.123.8 HORIZONTAL TERMINATION16.5Simple venting confi guration (only one 45° and 90° elbow)(HT) < (VT)For vent confi gurations

Page 7 - 2.4 RATING PLATE INFORMATION

15W415-0778 / D / 09.13.1216.5_2Simple venting confi guration (only one 45° and 90° elbow)(HT) > (VT)For vent confi gurations requiring more than one

Page 8 - 3.0 VENTING

16W415-0778 / D / 09.13.123.9 VERTICAL TERMINATION(HT) < (VT) Simple venting configurations.See graph to determine the required vertical rise VT fo

Page 9

17W415-0778 / D / 09.13.12(HT) > (VT) Simple venting configurations.See graph to determine the required vertical rise VT for the required horizonta

Page 10

18W415-0778 / D / 09.13.124.0 INSTALLATION4.1 WALL AND CEILING PROTECTIONFor clearance to combustible materials from the vent pipe, see “FRAMING” sec

Page 11 - 3.3.1 PERISCOPE TERMINATION

19W415-0778 / D / 09.13.12This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal loc

Page 12

2W415-0778 / D / 09.13.12TABLE OF CONTENTSNOTE: Changes, other than editorial, are denoted by a vertical line in the margin.1.0 INSTALLATION OVERVIEW

Page 13 - -135° when combined

20W415-0778 / D / 09.13.124.1.2 VERTICAL INSTALLATION4.2 USING FLEXIBLE VENT COMPONENTSFor safe and proper operation of the appliance, follow the ven

Page 14 - 3.8 HORIZONTAL TERMINATION

21W415-0778 / D / 09.13.124.2.1 HORIZONTAL AIR TERMINAL INSTALLATIONA. Stretch the inner fl ex pipe to the required length taking into account the add

Page 15 - ) > (V

22W415-0778 / D / 09.13.124.2.2 VERTICAL AIR TERMINAL INSTALLATION4.2.3 VENT CONNECTIONA. Fasten the roof support to the roof using the screws provid

Page 16 - ) < (V

23W415-0778 / D / 09.13.124.3 USING RIGID VENT COMPONENTSThe vent system must be supported approximately every 3 feet for both vertical and horizonta

Page 17

24W415-0778 / D / 09.13.124.3.3 VERTICAL AIR TERMINAL INSTALLATIONA. Move the appliance into position.B. Fasten the roof support to the roof using t

Page 18 - 4.0 INSTALLATION

25W415-0778 / D / 09.13.124.4 MOBILE HOME INSTALLATIONThis appliance is also certifi ed to be installed as an OEM (Original Equipment Manufacturer) in

Page 19 - 4.1.1 HORIZONTAL INSTALLATION

26W415-0778 / D / 09.13.1230.1AInstallation and servicing to be done by a qualifi ed installer.A. Move the appliance into position and secure.B. If

Page 20 - 4.1.2 VERTICAL INSTALLATION

27W415-0778 / D / 09.13.125.0 FRAMING!WARNINGRISK OF FIRE!IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT

Page 21 - PIPE

28W415-0778 / D / 09.13.12Minimum clearance to combustible construction from appliance and vent surfaces:Sides, back, bottom and top of the unit 0&

Page 22 - 4.2.3 VENT CONNECTION

29W415-0778 / D / 09.13.12The appliance requires a minimum enclosure height of 45 1/2". For temperature requirements, the enclosure space around

Page 23 - 20"

3W415-0778 / D / 09.13.121.0 INSTALLATION OVERVIEWSee the section“MINIMUM MANTEL AND ENCLOSURE CLEARANCES”See the section “FRAMING” and “MINIMUM MANTE

Page 24

30W415-0778 / D / 09.13.125.3 ALCOVE INSTALLATIONAPPLIANCERECESS OR ALCOVE AREA NOTE: Recesses or alcoves above the appliance can be made as deep as d

Page 25 - 4.4 MOBILE HOME INSTALLATION

31W415-0778 / D / 09.13.1255.1AA. Attach the nailing tabs to the corner posts using the 2 sheet metal screws sup-plied. Secure through the centre of

Page 26 - 4.5 GAS INSTALLATION

32W415-0778 / D / 09.13.126.2 L42 LOUVRE INSTALLATIONABABSLOTTABSLOTHINGECLIP57.1AUPPER LOUVRESInsert the louvre tabs into the slots located at the t

Page 27 - 5.0 FRAMING

33W415-0778 / D / 09.13.126.5 LOG PLACEMENTPhazertm logs and glowing embers, exclusive to Napoleon® Fireplaces, provide a unique and realistic glowing

Page 28

34W415-0778 / D / 09.13.1232.1Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust fo

Page 29

35W415-0778 / D / 09.13.127.0 OPTIONAL BLOWER INSTALLATIONINSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grou

Page 30 - 5.3 ALCOVE INSTALLATION

36W415-0778 / D / 09.13.128.0 OPERATIONEnsure that a continuous gas flow is at the burner before installing the door. When lit for the first time, the

Page 31 - 6.0 FINISHING

37W415-0778 / D / 09.13.129.0 ADJUSTMENTS9.1 PILOT BURNER ADJUSTMENTAdjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direc

Page 32 - 6.4 GRATE INSTALLATION

38W415-0778 / D / 09.13.129.3 FLAME CHARACTERISTICSIt’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them

Page 33 - 6.5 LOG PLACEMENT

39W415-0778 / D / 09.13.1210.1 CARE OF GLASS5.1DO NOT CLEAN GLASS WHEN HOT! DO NOT USE ABRASIVE CLEANERS TO CLEAN GLASS. Buff lightly with a clean dr

Page 34 - 6.10 LOGO PLACEMENT

4W415-0778 / D / 09.13.123.1C!WARNING• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.• ANY CHANGES TO THIS APPLIANCE O

Page 35

40W415-0778 / D / 09.13.1211.0 REPLACEMENTSContact your dealer or the factory for questions concerning prices and policies on replacement parts. Norma

Page 36 - 8.0 OPERATION

41W415-0778 / D / 09.13.12FLEXIBLE VENT KITSREF NO. PART NO. DESCRIPTIONGD420 (5 FT)29* W010-0772 5" FLEXIBLE VENT PIPE - (5 FT) C/W SPACERS29* W

Page 37 - 9.0 ADJUSTMENTS

42W415-0778 / D / 09.13.12ACCESSORIESREF NO. PART NO. DESCRIPTION54* GD36 THERMOSTATIC SENSOR CONTROL KIT - FOR USE WITH GD65 ONLY55* W500-0033 VARIAB

Page 38 - MAINTENANCE

43W415-0778 / D / 09.13.1212.0 TROUBLESHOOTINGSYMPTOM PROBLEM TEST SOLUTIONMain burner goes out; pilot stays on.Pilot fl ame is not large enough or not

Page 39 - 10.2 PLATED PARTS

44W415-0778 / D / 09.13.12SYMPTOM PROBLEM TEST SOLUTIONPilot will not light. No spark at pilot burner. - Check if pilot can be lit by a match. - Chec

Page 40 - 11.0 REPLACEMENTS

45W415-0778 / D / 09.13.1242.3_3SYMPTOM PROBLEM TEST SOLUTIONWhite / grey fi lm forms. Sulphur from fuel is being deposited on glass, logs or combustio

Page 41 - ACCESSORIES

46W415-0778 / D / 09.13.1213.0 WARRANTYCONTINENTAL® warrants its products against manufacturing defects to the original purchaser only. Registering yo

Page 42

47W415-0778 / D / 09.13.1214.0 SERVICE HISTORY43.1

Page 43 - 12.0 TROUBLESHOOTING

48W415-0778 / D / 09.13.12

Page 44 - SYMPTOM PROBLEM TEST SOLUTION

5W415-0778 / D / 09.13.122.1 DIMENSIONS2.2 GENERAL INSTRUCTIONSTHIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform

Page 45

6W415-0778 / D / 09.13.122.3 GENERAL INFORMATIONWhen the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommenda

Page 46 - 13.0 WARRANTY

7W415-0778 / D / 09.13.122.4 RATING PLATE INFORMATIONINSTALLER: It is your responsibility to check off the appropriate box on the rating plate accord

Page 47 - 14.0 SERVICE HISTORY

8W415-0778 / D / 09.13.123.0 VENTINGHorizontal runs may have a 0" rise per foot in all cases using Simpson Dura-Vent, Selkirk Direct Temp, Ameri-

Page 48 - W415-0778 / D / 09.13.12

9W415-0778 / D / 09.13.123.1 VENTING LENGTHS AND COMPONENTSUse only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or M

Commentaires sur ces manuels

Pas de commentaire