1
W415-0802 / B / 10.29.10
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
1.24
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.continental replaces.com • ask@continental re.on.ca
SAFETY INFORMATION
!
WARNING
If the information in these instructions are
not followed exactly, a re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
$10.00
CDV36NTR
BCDV36NTR
NATURAL GAS MODEL
CDV36PTR
BCDV36PTR
PROPANE GAS MODEL
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33 ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
BCDV36 Illustrated
Vue de la page 0
1 2 3 4 5 6 ... 59 60

Résumé du contenu

Page 1 - OPERATING INSTRUCTIONS

1W415-0802 / B / 10.29.10INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.INSTALLATION AND OPERATIN

Page 2 - TABLE OF CONTENTS

10W415-0802 / B / 10.29.10** When a vertical rise is used as part of the venting confi guration, a 0" rise per foot is acceptable.3.1 VENTING LEN

Page 3 - 1.0 INSTALLATION OVERVIEW

11W415-0802 / B / 10.29.103.2 TYPICAL VENT INSTALLATION16" MINIMUM16" MINIMUM40 FT MAXIMUM3 FTMINIMUM40 FT MAXIMUM3 FTMINIMUMTOP VENTREAR V

Page 4 - 2.0 INTRODUCTION

12W415-0802 / B / 10.29.1020" MAXIMUM20" MAXIMUM24" MAXIMUM24 1/4" MINIMUM PLUS RISE*24 1/4" MINIMUM PLUS RISE*24" MINIM

Page 5 - 2.2 BCDV36 DIMENSIONS

13W415-0802 / B / 10.29.1020” MAXIMUM6” RISE MINIMUM3.3 SPECIAL VENT INSTALLATIONS3.3.1 PERISCOPE TERMINATION (CDV36 AND BCDV36)12" MINIMUMTO GR

Page 6 - 2.3 GENERAL INSTRUCTIONS

14W415-0802 / B / 10.29.103.4 MINIMUM AIR TERMINAL LOCATION CLEARANCESINSTALLATIONSCANADA U.S.A.A 12” 12” Clearance above grade, veranda porch, deck

Page 7 - 2.4 GENERAL INFORMATION

15W415-0802 / B / 10.29.103.5 VENTING APPLICATION FLOW CHART13.1TOP EXITHorizontal TerminationVertical TerminationVertical rise is equal to or greate

Page 8 - 2.5 RATING PLATE INFORMATION

16W415-0802 / B / 10.29.103.6 DEFINITIONS14.1For the following symbols used in the venting calculations and examples are:> - greater than> - equ

Page 9 - 3.0 VENTING

17W415-0802 / B / 10.29.103.8 TOP EXIT HORIZONTAL TERMINATION(HT) < (VT) Simple venting configuration (only one 90° elbow)See graph to determine t

Page 10

18W415-0802 / B / 10.29.10(HT) > (VT) Simple venting configuration (only one 90° elbow)See graph to determine the required vertical rise VT for the

Page 11

19W415-0802 / B / 10.29.103.9 REAR EXIT HORIZONTAL TERMINATIONFor vent configurations requiring more than two 90° elbows, the following formulas appl

Page 12

2W415-0802 / B / 10.29.10NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.TABLE OF CONTENTS1.0 INSTALLATION OVERVIEW

Page 13 - 3.3.2 CORNER TERMINATION

20W415-0802 / B / 10.29.10Simple venting configuration (only two 90° elbows)See graph to determine the required vertical rise VT for the required hori

Page 14

21W415-0802 / B / 10.29.103.10 TOP OR REAR EXIT VERTICAL TERMINATIONSimple venting configurations.See graph to determine the required vertical rise V

Page 15

22W415-0802 / B / 10.29.10Simple venting configurations.See graph to determine the required vertical rise VT for the required horizontal run HT.REQUIR

Page 16 - 3.7 ELBOW VENT LENGTH VALUES

23W415-0802 / B / 10.29.10Example:V1 = 1.5 FTV2 = 5 FTVT = V1 + V2 = 1.5 + 1 + 5 = 6.5 FTH1 = 1 FTH2 = 1 FTH3 = 10.75 FTHR = H1 + H2 + H3 = 1

Page 17 - ) < (V

24W415-0802 / B / 10.29.104.3 BCDV36 REAR EXIT4.4 BCDV36 TOP VENTFrom inside the fi rebox, insert the 4" fl ue pipe / gasket assembly (provided)

Page 18 - ) > (V

25W415-0802 / B / 10.29.105.1.1 CDV36 HORIZONTAL INSTALLATIONA. Assemble the two halves of the vent sleeve by aligning the holes that come together t

Page 19

26W415-0802 / B / 10.29.105.1.2 BCDV36 HORIZONTAL INSTALLATION5.1.3 VERTICAL INSTALLATIONThis application occurs when venting through a roof. Installa

Page 20

27W415-0802 / B / 10.29.105.2 USING FLEXIBLE VENT COMPONENTSFor safe and proper operation of the appliance, follow the venting instructions exactly.A

Page 21

28W415-0802 / B / 10.29.105.2.2 VERTICAL AIR TERMINAL INSTALLATIONA. Fasten the roof support to the roof using the screws provided. The roof support

Page 22

29W415-0802 / B / 10.29.105.3 USING RIGID VENT COMPONENTSThe vent system must be supported approximately every 3 feet for both vertical and horizonta

Page 23 - 4.1 CDV36 REAR EXIT

3W415-0802 / B / 10.29.101.0 INSTALLATION OVERVIEWSee the section “MINIMUM ENCLOSURE CLEARANCES” for drywall (or other combus-tible material).See the

Page 24 - 5.0 INSTALLATION

30W415-0802 / B / 10.29.10Vertical terminations running longer than 15 feet may display a very active fl ame. If this appearance is not desirable, the

Page 25

31W415-0802 / B / 10.29.105.4 MOBILE HOME INSTALLATIONThis appliance is certifi ed to be installed as an OEM (Original Equipment Manufacturer) install

Page 26 - 5.1.3 VERTICAL INSTALLATION

32W415-0802 / B / 10.29.105.5 GAS INSTALLATION30.1AInstallation and servicing to be done by a qualifi ed installer. Do not use open fl ame.A. Move the

Page 27 - PIPE

33W415-0802 / B / 10.29.105.6 OPTIONAL WALL SWITCHFor ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed

Page 28 - ROOF SUPPORT

34W415-0802 / B / 10.29.10 Minimum clearance to combustible construction from appliance and vent surfaces: Combustible Framing: - 0" to stand

Page 29 - 20"

35W415-0802 / B / 10.29.10Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2" away from the side of

Page 30

36W415-0802 / B / 10.29.106.2 BCDV36 FRAMING!WARNINGRISK OF FIRE!IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN C

Page 31 - 5.4 MOBILE HOME INSTALLATION

37W415-0802 / B / 10.29.10Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2" away from the side of

Page 32 - 5.5 GAS INSTALLATION

38W415-0802 / B / 10.29.10BRICKCOMBUSTIBLE NON-COMBUSTIBLE2”1”0” IF NON-COMBUSTIBLE FINISHING IS USEDSUCH AS BRICK AND STONE. 24” MINIMUMPLUS RISE*2”

Page 33 - 6.0 FRAMING

39W415-0802 / B / 10.29.10BRICKCOMBUSTIBLE NON-COMBUSTIBLE2”1”0” IF NON-COMBUSTIBLE FINISHING IS USEDSUCH AS BRICK AND STONE. 24” MINIMUMPLUS RISE*2”

Page 34

4W415-0802 / B / 10.29.102.0 INTRODUCTION3.1B!WARNING• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.• ANY CHANGES TO

Page 35 - 52"

40W415-0802 / B / 10.29.106.5 BCDV36 NAILING TAB INSTALLATION55.1AA. Attach the nailing tabs to the corner posts using the 2 sheet metal screws sup-

Page 36 - 6.2 BCDV36 FRAMING

41W415-0802 / B / 10.29.107.0 FINISHING!WARNINGRISK OF FIRE!NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINI

Page 37 - /2"

42W415-0802 / B / 10.29.107.2 LOUVRE INSTALLATIONABCSLOTABCCLIPSCENTRE SLOTTABSLOTHINGE CLIP57.2UPPER LOUVRESInsert the louvre tabs into the slots loc

Page 38 - 6.3.1 CDV36

43W415-0802 / B / 10.29.107.3 LOG PLACEMENT!WARNINGFAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY LOGS SPECIFIC

Page 39 - 6.3.2 BCDV36

44W415-0802 / B / 10.29.10Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of the small log

Page 40

45W415-0802 / B / 10.29.10ROCK SUPPORT BRACKETLOG SUPPORT BRACKET!WARNING(RAK-ROCK ADAPTOR KIT IS NECESSARY WITH THIS KIT).REAL ROCKS MUST NOT BE USED

Page 41 - 7.0 FINISHING

46W415-0802 / B / 10.29.108.0 OPTIONAL BLOWER INSTALLATIONINSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grou

Page 42 - 7.2 LOUVRE INSTALLATION

47W415-0802 / B / 10.29.10Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle.The wire harne

Page 43 - 7.3 LOG PLACEMENT

48W415-0802 / B / 10.29.109.0 OPERATIONEnsure that a continuous gas flow is at the burner before installing the door. When lit for the first time, the

Page 44 - 7.7 LOGO PLACEMENT

49W415-0802 / B / 10.29.10CDV36 BCDV36NG 1/16” 1/16”LP 1/4” 1/4”This appliance has an air shutter that has been factory set open according to the char

Page 45 - 7.8 OPTIONAL ROCK KIT

5W415-0802 / B / 10.29.1038 1/2"33"7 1/2"27"141 /4"37 1/4"18 5/8"12 1/4"4" DIA.7" DIA.3"51/2&qu

Page 46

50W415-0802 / B / 10.29.10It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations prov

Page 47

51W415-0802 / B / 10.29.105.1DO NOT CLEAN GLASS WHEN HOT! DO NOT USE ABRASIVE CLEANERS TO CLEAN GLASS. Buff lightly with a clean dry soft cloth. Clean

Page 48 - 9.0 OPERATION

52W415-0802 / B / 10.29.10COMMON COMPONENTSREF NO. PART NO. DESCRIPTION1* W225-0058 BLACK DOOR FRAME2 W357-0001 PIEZO IGNITER 3 W680-0004 THERMOPILE4

Page 49 - LP 1/4” 1/4”

53W415-0802 / B / 10.29.10COMMON FLEXIBLE VENT KITSREF NO. PART NO. DESCRIPTIONGD220 (5 FT) 25* W010-0397 4" FLEXIBLE VENT PIPE - (5 FT) C/W SPAC

Page 50 - MAINTENANCE

54W415-0802 / B / 10.29.10COMMON ACCESSORIESREF NO. PART NO. DESCRIPTION49 VS47KT VENT PIPE SHIELD50 GZ550-1KT BLOWER KIT51* GD36 THERMOSTATIC SENSOR

Page 51 - 11.2 CARE OF GLASS

55W415-0802 / B / 10.29.1054**63231122702501273065132021191718163532333634545671555759394449523158

Page 52 - 12.0 REPLACEMENTS

56W415-0802 / B / 10.29.1013.0 TROUBLE SHOOTINGSYMPTOM PROBLEM TEST SOLUTIONMain burner goes out; pilot stays on.Pilot fl ame is not large enough or no

Page 53 - COMMON ACCESSORIES

57W415-0802 / B / 10.29.10SYMPTOM PROBLEM TEST SOLUTIONPilot will not light. No spark at pilot burner. - Check if pilot can be lit by a match. - Chec

Page 54 - ACCESSORIES

58W415-0802 / B / 10.29.10CONTINENTAL® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty i

Page 55

59W415-0802 / B / 10.29.1043.115.0 SERVICE HISTORY

Page 56 - 13.0 TROUBLE SHOOTING

6W415-0802 / B / 10.29.102.3 GENERAL INSTRUCTIONS4.1ATHIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with loca

Page 57 - SYMPTOM PROBLEM TEST SOLUTION

60W415-0802 / B / 10.29.1016.0 NOTES44.1

Page 58 - 14.0 WARRANTY

7W415-0802 / B / 10.29.102.4 GENERAL INFORMATIONFOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! CDV36

Page 59 - 15.0 SERVICE HISTORY

8W415-0802 / B / 10.29.102.5 RATING PLATE INFORMATIONCERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.22b-2009, ANSI Z21.50b-2009 VENTED GAS FIREP

Page 60 - 16.0 NOTES

9W415-0802 / B / 10.29.103.0 VENTING7.1THIS APPLIANCE USES A 4” EXHAUST / 7” AIR INTAKE VENT PIPE SYSTEM.Refer to the section applicable to your insta